Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. Stop the machine on level ground when cleaning or changing the coolant. To restrict the formation of rust and scale in hard water areas, add Komatsu genuine corrosion resistant KI-2 (pow- der) to the cooling water. Never use commercial available anti-corrosive agents (made by Fleetguard, etc.). When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mix- ing rate table given below.

It is actually better to estimate a temperature about 10°C lower when deciding the mixing rate. Mixing rate of water and antifreeze Min. atmospheric temperature -5 -10 -15 -20 -25 -30 (‘C) Amount of antifreeze 5.1 6.6 7.9 9.0 10.1 11 (Iz) Amount of water 16.9 15.4 14.1 13.0 11.9 11 (PI We recommend use of an antifreeze density gauge to con- trol the mixing proportions. Use city water for the cooling water. If river water, well water or other such water supply must be used, contact your Komatsu distributor. 3-25