Komatsu — 17. GUIDES TO MAINTENANCE

17. GUIDES TO MAINTENANCE Welding instructions: l Turn off the engine starting switch. l Do not apply more than 200 V continuously. l Connect grounding the cable within 1 m from the area to be welded. l Avoid seals or bearings from being between the area to be welded and the position of grounding point. Fire prevention: Use nonflammable cleaner or light oil for cleaning parts. Keep flame or cigarette light away from light oil. Clamp faces: When O-rings or gaskets are removed, clean the clamp faces and replace the O-rings and gas- kets with new ones. Be sure to fit O-rings and gaskets when assembling. Objects in your pockets:

Keep your pockets free of loose objects which can fall out and drop into the machinery; espe- cially when you work on the machinery while bending over it. Checking undercarriage: When working in rocky areas, check for damage to the undercarriage and for looseness, flaws, wear and damage in bolts and nuts. Loosen the track tension a little when working in such areas. Cleaning machine: l Do not direct a high-pressure jet directly at the radiator. l Do not splash water over the electrical equipment. Pre- and post-work checks: Before starting work in mud, rain, snow or at seashore, check plugs and valves for tightness.

Wash the machine immediately after the work to protect components from rusting. Lubricate components more frequently than usual. Be sure to lubricate work equipment pins daily if they are submerged in water. 3-3