DRESSTA Co. Ltd. 560C99/1E — 5.7.1. SERVICE BRAKE SYSTEM

MAINTENANCE SECTION 5 Page 19 AIR CLEANING SYSTEM indicated by a loss of indicator operation and can be checked as follows: Remove the pre-cleaner hood 12, Fig. 5.9. Start the engine and operate at low idle. Gradually seal off the air intake opening with a flat piece of cardboard until it is almost completely covered. If the red signal band of the indicator fails to rise and lock in position, the service indicator orifice is plugged. Once detected , the leak must be located and corrected immediately and service indicator orifice fitting cleaned or replaced to regain the full advantage of the service indicator. Service the indicator orifice fitting as follows: 1.

Disconnect the indicator tube from orifice fitting at the air cleaner elbow. 2. Remove the orifice fitting from the air cleaner elbow. 3. Wash the orifice in solvent and blow with compressed air. Clean the orifice opening with wire in the direction opposite to the air flow, if necessary. 4. Install the orifice fitting and service indicator. 5.6.5. PRECLEANER HOOD The dome of the precleaner hood 12, Fig. 5.9. serves as a rain shield and the screen prevents chaff and course dirt from getting into the air cleaner. Keep this screen clean from all chaff, oil or dust. Clogged holes in the screen will reduce the power of the engine by restricting the flow of air.

Loosen clamp screw 11 on the precleaner hood. Twist and pull upward to remove the cap. Use compressed air to clean the screen. If compressed air is not available, wash in clean hot water or water containing a small amount of nonsudsing detergent. CAUTION: Never wash precleaner installed on the machine as water may penetrate to the engine. 5.7. BRAKES 5.7.1. SERVICE BRAKE SYSTEM A wheel loader is equipped with “wet” brakes inboard mounted close to the planetaries of the drive axles. They do not require servicing during the operation of a machine. The brake system is supplied with a multi-piston pump with output compensation driven directly from the engine (engine mounted).

The brake cooling is secured by a separate cooling system supplied by a gear pump (driven from the torque converter). Both systems and drive system of the machine operate in one hydraulic system, with common oil reservoir in transmission. The brake system is equipped with hydraulic accumulators protecting emergency braking if the engine fails to operate. WARNING! The brake system pump is driven directly by the engine. The brake system is inoperative with the engine stopped. The hydraulic accumulators secure emergency braking only. The service brake system is divided into two separate circuits: front wheels brake circuit, rear wheels brake circuit.

These circuits can operate independently securing safe operation of a wheel loader. The service brake is actuated with the brake pedal from the operator’s cab. Increasing gradually pressure exerted on the brake pedal the required braking effect is obtained. The more the pedal is depressed the stronger the braking effect. DRESSTA OM560C99/1E