MACHINE TRANSPORT AND STORAGE SECTION 3 Page 7 MACHINE STORAGE FUEL PREP 1000 NALCO CHEMICAL COMPANY 2901 BUTTERFIELD ROAD OAK BROOK, ILLINOIS 60521, USA or Machine Distributor WARNING: Corrosion inhibitors are volatile and flammable. Use them only in a well-ventilated area. Keep flames and sparks away. DO NOT SMOKE. Store a container in a cool, well-ventilated place. CAUTION: Avoid prolonged exposure to volatile corrosion inhibitors because eye and skin irritation may occur. 10. It is recommended to use volatile corrosion inhibitor ("VCI") in the fuel tank.
The "VCI" provides corrosion protection by contact with the metal, and in a closed system, the vapors provide sufficient protection for areas that are not in contact with the oil. When using VCI per HMS B00- 0006 pour 120 of volatile corrosion inhibitor for each 100 l of total fuel capacity. The "VCI" may be purchased from: NOX RUST VCI #105 OIL DAUBERT CHEMICAL COMPANY 1200 JORIES BLVD. OAK BROOK, ILLINOIS 60521, USA or Machine Distributor 11. Deaerate the fuel system . Refer to FUEL SYSTEM Section 5. 12. Start the engine and run idle at 1400 to 1600 rpm for 4 minutes and then stop the engine. 13. Lubricate all points of the machine as outlined in the "SERVICE GUIDE" in Section 5.
IMPORTANT: Be sure to oil or grease all linkage connections, joints, nuts, pins, shafts, and bushings not covered in the "SERVICE GUIDE". 14. Drain the engine oil, replace the engine oil filters and fill them with proper grade of oil. Refer to ENGINE Section 5. 15. Add 15 ml VCI for each liter of engine oil to the crankcase. (example: if the total capacity of the crankcase is 10 l add 150 ml VCI). 16. Start the engine and run it idle at 1400 to 1600 rpm for 30 seconds and then stop the engine. 17. Remove the air precleaner. 18. Seal all external openings (i.e. engine exhaust outlet, filler caps, breathers, etc.) with tape wide enough to cover the opening, regardless of its size. NOTE:
When sealing with tape, be sure to extend tape approximately one inch (25 mm) beyond opening to insure a good seal. 19. Pour 120 ml VCI to the intake manifold to prevent corrosion of the space between piston and bottom part of the head. 20. It is recommended to pour 390 ml VCI type 1 oil per HMS B00-0006 (KDC Standard) to the hydraulic reservoir. 21. Remove the batteries and place them on wooden skids. Then, store them in a cool, clean, dry, well-ventilated place away from the areas provided for storing or dispensing fuel and oil, not near any heat source and preferably where the temperature range is between 0° to +21 °C . Be sure the batteries are fully charged. DRESSTA OM560C99/1E