DRESSTA Co. Ltd. 560C99/1E — 4.11. ELETRICAL MASTER SWITCH

OPERATING SECTION 4 Page 25 CAB DOOR LATCH To lock the door depress the arm (with a foot) when the door is in fully open position. The pin 2 will engage the cutout of arm 1. The door will be released automatically when moved further to open (until the limiting strip is fully tightened). 4.10. ACCESS PANEL “T” HANDLE The access panels to service the hydraulic reservoir filters, the air cleaner elements, and the batteries are all locked and unlocked using the "T” handle. It is stored in rubber holder attached to the RH side of the instrument panel. Fig. 4.17. Access Panel “T” Handle 4.11. ELECTRICAL MASTER SWITCH Fig. 4.18.

Electrical System Master Switch The switch is located on the LH side of the hydraulic tank behind the cab and is connected in series between the battery positive terminal (+) and receivers, thus turning "ON" or "OFF” battery voltage to all electrical systems. The master switch must always be turned to the "ON" position when the engine is running to prevent any damage to the alternator and/or electrical system. WARNING: Before servicing the machine, turn off the electrical system master switch and remove the key. Tag the machine to warn against starting the engine. DRESSTA OM560C99/1E