MAINTENANCE B. Twist off the point(s) from the adapter(s). The adapters themselves can be removed after mounting nuts and bolts have been removed. C. Make sure adapter is clean and install the new point(s) on the adapter(s), and secure with the pins removed in step 2A. Make sure the pin guide rib faces back and that the pins fit flush with the top of the point. D. Proceed to step 6. 3. Remove nuts and bolts (1) and (2) then remove the teeth (3). 4. Clean the mounting surface of the bucket teeth. If the mounting surface is worn, repair and correct it before installing new teeth. 5. Install new teeth and use shims to eliminate any clearance between the teeth and the top surface of the bucket.
Minimum clearance . . . . . . . . less than 0.5 mm (0.02 in) 6. To prevent any gap from occurring between the tooth and the tip of the bucket, slightly loosen the hardware (temporarily) then hit the tip of the tooth with a hammer. Tighten the mounting hardware. Mounting nuts . . . . . . . 1265 ± 69 N 7. Check the mounting bolts’ torque after operating the equipment for several hours, and tighten if necessary. 3-36 WA420-3MC