24. SERVICE PROCEDURE 9. When the water comes up to near the water filler port, open drain valve 3 , drain plugs 4 and 5 , run the engine at low idling, and continue to run water through the system until clean colorless water comes out. When doing this, adjust the speed of filling and draining the water so that the radiator is always full. 10. When the water is completely clean, stop the engine, close drain valve 3 , drain plugs 4 and 5 . 11. Replace the corrosion resistor cartridge and open valve 1 . For details of replacement of the corrosion resistor, see “24.8 EVERY 1000 HOURS SERVICE”. 12. Supply the antifreeze and city water until it overflows from the water filler.
For mixing ratio of the untifreeze and city water, decide by using the “Mixing rate of water and antifreeze”. 13. To remove the air in the cooling water, run for five minutes at low idling, then for another five minutes at high idling. When doing this, leave radiator cap 2 off. 14. Stop the engine, wait for about three minutes, add cooling water up to near the radiator water filler port, then tighten the cap. 3-28