Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE 24.2.9 CHECK APS (automatic priming system) Check APS when the ambient temperature drops to 15°C. 1. Open fuel valve 1 of automatic priming system, and remove hose 2 at entrance of nozzle. 2. Move feed pump 3 up and down, and bleed air until air bubbles stop coming out of opening of hose 2 . Perform the next test the same way. Is there a fuel leak? Is the fuel piping plugged? 3. After putting preheater switch in ON position and after returning to auto, check the following items: Does the pre-heat monitor lamp turn off after about 80 seconds? When the pre-heat monitor lamp goes off, are the outside of the glow plugs (2 pieces) warm?

When hand is removed from pre-heater switch when in ON position, switch will return to AUTO position automatically. 4. The fuel hose should be checked at the same time. If the hose is found to have cracks or to be hardened by ageing, it should be replaced with a new one. Further, loosen hose clamps should also be tightened. 3-33