24. SERVICE PROCEDURE 24.6.4 CHECK AIR CONDITIONER COMPRESSOR BELT TENSION, ADJUST (if equipped) Checking The belt should normally deflect by about 10 mm (0.4 in) when pressed with the finger (with a force of approx. 58.8 N (6 kgf)) at a point midway between the drive pulley and compressor pulley. When belt tension gauge is used, it is considered normal for tension to remain in the range of 353 – 530 N (36 – 54 kgf). Adjusting 1. Loosen bolts 1 and 2 . 2. Move compressor 3 so that so that the deflection is approx. 10 mm (0.4 in) (at a force of approx. 58.8 N (6 kgf)). Do not push compressor 3 directly with a bar; insert a wooden block and push the block with the bar. 3.
Tighten bolts 1 and 2 to fix compressor 3 in position. 4. Check each pulley for damage, wear of the V-groove, and wear of the V-belt. In particular, be sure to check that the V-belt is not touching the bottom of the V-groove. 5. Replace the V-belt if it has stretched, leaving no allowance for adjustment, or if there is any cut or crack on belt. After operating the machine for one hour with a newly ex- changed V-belt, test and adjust the V-belt again. 3-61