Komatsu — 24.6 EVERY 250 HOURS SERVICE

24. SERVICE PROCEDURE 24.6.4 CHECK AIR CONDITIONER COMPRESSOR BELT TENSION, ADJUST (if equipped) Checking The belt should normally deflect by about 10 mm (0.4 in) when pressed with the finger (with a force of approx. 58.8 N (6 kgf)) at a point midway between the drive pulley and compressor pulley. When belt tension gauge is used, it is considered normal for tension to remain in the range of 353 – 530 N (36 – 54 kgf). Adjusting 1. Loosen bolts 1 and 2 . 2. Move compressor 3 so that so that the deflection is approx. 10 mm (0.4 in) (at a force of approx. 58.8 N (6 kgf)). Do not push compressor 3 directly with a bar; insert a wooden block and push the block with the bar. 3.

Tighten bolts 1 and 2 to fix compressor 3 in position. 4. Check each pulley for damage, wear of the V-groove, and wear of the V-belt. In particular, be sure to check that the V-belt is not touching the bottom of the V-groove. 5. Replace the V-belt if it has stretched, leaving no allowance for adjustment, or if there is any cut or crack on belt. After operating the machine for one hour with a newly ex- changed V-belt, test and adjust the V-belt again. 3-61