JCB — 2.pdf (p.2)

Section C - Electrics Basic System Operation Auto Boost Pressure Auto Boost Pressure Operation C049920-1 Fig 30. The auto pressure boost function is only available when the excavator is in auto mode. By default it is not available in precision and economy mode and is permanently on (although not indicated on the EMS) in lifting mode. In auto mode, when the boost pressure switch is closed the 2 stage relief valve, ECU1 o/p 24 (C-27) is energised (according to the logic diagram, K Fig 31. ( T C-28) ). This allows a pressure increase in the excavating hydraulic circuit thus generating extra digging force.

If the boost pressure switch is seen for less than 1.5 seconds then the 2 stage relief valve is energised until the boost pressure switch is de-energised, then the logic sequence is reset and will allow the sequence to be started over again. If the boost pressure switch is seen for more than 1.5 seconds then the 2 stage relief valve should stay open for a further 1.5 seconds. The valve cannot be re-energised for 9 seconds after the end of the last activation However during travel operation (denoted by the travel pilot switch input) the 2 stage relief valve is energised.

If the boost pressure switch is closed when the travel pressure switch is valid, the solenoid will remain energised C-27 C-27 9803/9880-3