JCB — 8.pdf (p.8)

Section C - Electrics Basic System Operation Engine Start/Stop Engine Start/Stop Operation C031471GB-2 Fig 42. Starting/Stopping the engine Pressing the Emergency Stop Button When the ignition key is turned to the crank position, 24v is fed to: If the emergency stop button on the FSP is pressed whilst the engine is running, the 24v from ECU o/p 22, (C-26) to the Emergency Stop Relay is stopped. The relay is de- energized, feeding 24v from the battery to the ECM i/p V47 - ENGSTP, and the engine is stopped. the ECU on i/p 28, (A-26) - Crank, the ECM on i/p V46 - START, the Safety Relay. At the same time the EMS will display the message 'EMER STOP'.

If the ignition is switched off and then back on, the system retains the emergency stop function until the emergency stop button on the FSP is pressed again. The ECU provides 24v from o/p 22 (C-26), through the closed contacts of the Emergency Stop button on the FSP to the coil of the emergency stop selay. The relay is energized, removing 24v from the ECM i/p V47 - ENGSTP. The safety relay provides an output to the starter motor, and the ECM starts the engine. Engine start is disabled unless the lever lock arm is raised. if the ignition is switched on and the lever lock arm is raised, the emergency stop remains off and the engine will not start.

If cranking is attempted while the lever lock arm is down, the LIFT_LEVER message is displayed on the EMS and the servo isolator LED will flash on the EMS for the duration of the cranking. When the engine is running, if the ignition key is switched off, the 24v from ECU o/p 22 (C-26) to the emergency stop relay is removed. The relay is de-energized, feeding 24v from the battery to the ECM i/p V47 - ENGSTP, and the engine is stopped. C-40 C-40 9803/9880-3