Section C - Electrics Basic System Operation Limp Mode system Limp Mode system Operation EMS Limp Mode 16 Ignition 15 Redundancy ECU1 Key Switch 2A Limp mode Switch 1 Sys B-5 +V ign 2 FSP Emer. Stop O/p 22 (C-26) O/p 21 (C-36) Lever Lock Sol.Valve I/p 32 (A-33) Lever Lock Switch O/p 34 (C-38) Swing Lock Sol. Valve C030750GB-2 Fig 44. In the event of a ECU1 failure, the redundancy switch allows the function of: The emergency stop switch in the facia switch panel is fed from the ECU1 o/p 22 (C-26). The lever lock and swing lock functions are fed from the ECU1 o/p 21 (C-36). 1 Lever lock 2 Swing lock The lever lock and swing lock functions are fed from the redundancy switch via a diode.
3 Emergency shutdown The EMS will permanently display a "LIMP HOME" message and all bar graph bars will illuminate together and flash on/off at half second intervals. The buzzer will sound, this can be cancelled by pressing the ACK button. In the normal position, the redundancy switch feeds the ignition voltage to the ECU1 and the redundancy i/p of the EMS. The engine will run at the default engine speed (approx. 1600 rpm). In the "redundancy" position, the ignition voltage is fed to the "emergency stop" switch in the facia switch panel, via a diode. C-42 C-42 9803/9880-3