Section C - Electrics Basic System Operation Soft/Hard (Cushion) Soft/Hard (Cushion) Operation C005600GB-2 Fig 59. The soft/hard mode allows the operator to select the response of the hydraulic circuits, soft being controlled and hard being fierce when de-selecting boom and dipper functions. Soft mode is the default setting when starting the machine. To change to hard mode the operator must select the option by pressing cushion switch on the facia switch panel. Cushion solenoid output ECU o/p 28 (C-25) is energised. The hard mode is cancelled either by turning the ignition off, or by pressing the cushion switch for a second time. C-58 C-58 9803/9880-3