Section C - Electrics Basic System Operation Slew lock (100% Slew Brake) Slew lock (100% Slew Brake) Operation C028430GB-2 Fig 63. The slew lock prevents any slew operation of the machine, even if the LH joystick is moved. It acts as 100% slew parking brake and disables the slew pilot circuit, by applying equal pressure on either side of the slew spool in the main valve block (slew shut off). 5 seconds after the Slew Lock button is pressed the slew lock solenoid is energised, opening the slew brake cylinder to tank and applying 100% braking force. The slew lock is de-activated by a second press of the fascia switch.
This causes the switch status indicator and the EMS warning lamp to be extinguished. The ECU1 de- energises the slew lock and slew shut off solenoid valves. The slew parking brake will not be re-energised until an input from the slew pilot pressure switch is seen. The lock is operated by pressing the slew lock switch on the fascia switch panel. When pressed the status indicator illuminates. The EMS displays the message "SWING LOCK", and the warning light illuminates. The EMS transmits the slew lock request to the ECU1 via the CAN communications link.
The slew shut off solenoid is energised (effectively isolating the joysticks) and slew parking brake solenoids is left de-energised by the ECU1. By Default upon start slew lock is automatically disengaged. C-64 C-64 9803/9880-3 Swing Lock Swing Pilot Psw Swing Lock Sol Valve Swing Parking Brake Sol Valve Swing shut off Sol Valve FS2 i/p29(A-36) o/p8 (C-3) o/p9 (C-4) o/p10 (C-16) 8 9 8 9 8 9 8 8 (=100% brake) 9 9 + 5 Sec 9 8 (=100% brake) 9