JCB — 23.pdf (p.23)

Section C - Electrics Basic System Operation Fuel Level Sensor/Warning Fuel Level Sensor/Warning Operation C005650GB-2 Fig 72. A float sensor is fitted to the fuel tank to measure the level of fuel in the tank. A magnetic float rises up a tube containing a series of 5 ohm resistors with switches in parallel. The fuel level is displayed to the operator by means of a bar graph gauge. The actual values can be displayed via the EMS SET+MODE menu. Both the actual value and bar graph values should be an average of consecutive readings to provide a degree of dampening to prevent false readings Text warnings are provide for both reserve fuel and low fuel conditions.

Low fuel is also backed up by a flashing bar graph. The low fuel condition must be present for one consecutive minute before the "LOW FUEL" warning is displayed. The reserve fuel condition must be present for one consecutive minute before the "RES FUEL" warning is displayed. C-76 C-76 9803/9880-3