JCB — 29.pdf (p.29)

Section C - Electrics Basic System Operation Quick hitch (option) Quick hitch (option) Operation C005730GB-2 Fig 84. !M WARNING When using Quick Hitch Type 2, the attachment can become unexpectedly disengaged from the Quick Hitch, when any of the following occurs: Power failure to the Electronic Control Unit (ECU). When the redundancy switch is engaged. If an electrical component in the Quick Hitch system should fail. When the quick hitch switch is activated the EMS will display the "Q/H DISCON?" message to verify the switch operation and the switch status indicator will illuminate. 0178 The Quick hitch option allows the operator to quickly change the attachment from within the cab.

If the "ACK" switch on the EMS is not pressed within 5 seconds then the display reverts to normal and the switch status indicator is extinguished. There are two types that can be fitted and they operate in different ways. The solenoid valve will only be energised/de-energised once the "ACK" button on the EMS is activated. This is included as a safety feature to prevent accidental operation of the quick hitch system. Quick hitch type 1 Q/H off = output is switched on Q/H on = output is switched off Once the "ACK" button is pressed the EMS displays the message "Q/H DISCON" and the ECU1 o/p 23 (C-28) is de-energised (type 1) or energised (type 2).

The buzzer is sounded while the quick hitch is disconnected. Quick hitch type 2 Q/H off = output is switched off Q/H on = output is switched on The system can be enabled and switched between types via the SET + MODE (20 seconds) menu: To reconnect quick hitch press "ACK". The EMS will display "Check Q/H" instructing the operator to visually check the quick hitch attachment is securely connected. Press "ACK" again to switch off buzzer. C-94 C-94 9803/9880-3 SET + MODE (20 secs) QH ENABLE? QH ON QH TYPE? QH TYPE 1 Scroll to Q/H option ACK Scroll up/down to toggle between ON and OFF, ACK ACK Scroll up/down to toggle between type 1 and 2 ACK