JCB — 30.pdf (p.30)

Section C - Electrics Basic System Operation Overload Caution (option) Overload Caution (option) Operation C049770GB-2 Fig 86. Overload caution is used as a warning to the operator that the machine is lifting a mass which is exceeding the safe load capacity of the machine. An overload is indicated after the overload pressure switch, ECU1 i/p 13 (A-27) has been activated. By default the overload override option is not enabled in A (Auto), E (Economy) & P (Precision) modes until the overload switch is selected. When selecting the overload switch on the facia switch panel the EMS displays the acknowledge message "OVERLOAD ON" and the staus LED illuminates.

A second press of the switch disables the overload override function and the status LED is extinguished. When entering L (Lifting) Mode, the overload override warning system is automatically activated. The status indicator for FS6 illuminates. The operation of overload switch will cancel the overload warning system. If a overload condition is reached whilst the overload function is selected, the EMS will display "OVERLOAD" and the buzzer will sound. C-96 C-96 9803/9880-3