JCB — 32.pdf (p.32)

Section C - Electrics Basic System Operation Hammer Only Hammer Only Operation C030430GB-1 Fig 90. The hammer is operated by pressing the foot pedal forward which supplies a pilot pressure signal to close the pressure switch and operate the option spool in the main control valve (MCV). When the pressure switch is closed, ECU 1 i/p 20 (A-11) senses the grounding of the pressure switch, which reduces the engine rpm to a level preset in the SET menu. The throttle potentiometer normally increases/decreases the engine rpm from idle to max engine speed but will not exceed the preset hammer value, regardless of its position.

The maximum "hammer revs" (engine rpm) can be set by the operator via the SET menu on the EMS. The up and down buttons will increase/decrease the rev/min value, by 25 rpm for each press. Whatever value is set by the operator is stored and becomes the new default value. The original default value for "Hammer RPM" is 1200 rev/ min. C-100 C-100 9803/9880-3