Section C - Electrics Basic System Operation Scrap Magnet Option Scrap Magnet Option Operation C030460GB-2 Fig 93. When a scrap handling magnet attachment is fitted to the machine, the high voltage required for its operation is supplied by an engine driven generator. If the minimum engine rpm is too low, the supply voltage to the magnet may decrease to the point where any material on the magnet may drop off. To prevent this the machine has the capability to set the minimum engine speed so that it doesn't fall below a predetermined level whilst the scrap magnet is being used. rpm. value in 50 rpm.
increments (allowable range to be the low idle setting to S mode full engine speed setting for the particular model). The default setting for the minimum engine speed is 1000 rpm. The rpm setting of this feature is stored and is used each time the machine is used whilst the scrap magnet function is enabled. The scrap magnet option is switched off through the EMS SET menu. The feature can be switched on or off and the minimum rpm set via the SET menu of the EMS by the "SCRAP MAG" option. When this feature is enabled the throttle volume potentiometer is re-scaled so that in the minimum position the engine rpm is that pre-set through the following procedure.
If a target value less than the machines idle rpm is selected, then the machine will default to the original Idle setting. Set the Minimum Engine RPM for Scrap Magnet Use Press the SET and MODE buttons on the EMS for 5 seconds then use the scroll buttons until "SCRAP MAG" is displayed. Press the ACK button (this will alternate the function on/ off). Set the display to "ON", the display will change between "MAG ON" and "MAG OFF"). Press the 'ACK' button, the display will change to "RPM 1000". Pressing the scroll buttons will then change the C-103 C-103 9803/9880-3