Section C - Electrics Service Procedure Wiring Harness Repair Wiring Harness Repair Introduction TC-004 !M CAUTION Instances do occur where it is necessary to incorporate auxiliary electrical components into existing electrical circuits and, although unlikely with present wiring harnesses, repair or replace specific individual wires within a harness. This will also apply to other machines in addition to those of manufacture. When the heater is in use, the reflector and the air coming out are extremely hot. Keep away to avoid accidental burns. Do not touch the reflector until it has had time to cool down after switching off.
If flame reappears at the reflector when the heater is in use, the catalytic element is damaged or used up. Stop work immediately and replace the heater. To ensure that either the inclusion of an auxiliary electrical component or a repair within a harness is completed to an acceptable standard it is strongly recommended that the following tools, equipment and procedures are always used. Note that JCB harnesses have an International Protection rating of 67 (I.P.67). ELEC-2-3 Repair Procedure Table 3. Tools Required The sheath covering of the recommended splice is heat shrunk onto the original wire insulation. This results in a seal and corresponding joint to IP 67 specifications.
!M CAUTION When installing Auxiliary Electrical Components always ensure that the additional load rating is suitable for that particular circuit. It is unacceptable to simply increase the fuse rating as this can cause overloading and consequential failure of wiring, along with failure of integral circuit components, which the fuse is protecting. 1 Cut the wire and remove the protective insulation for a suitable distance dependent upon the size of wire and splice to be used. For the splices detailed in K Table 3. ( T C-174) , the dimension is 7mm.
ELEC-2-1 !M WARNING In addition to the warnings incorporated into this procedure, extreme care should be taken when handling the gas heating tool to ensure that the flame does not damage or set fire to any items in the vicinity of the repair, i.e. other wires, floor panels, floor mats, sound proofing, paintwork, etc. This tool should not be used in any restricted location prohibiting the use of "Naked Flames" or where risk of explosive gas or similar safety parameters apply. No other heat source should be used to attempt a sealed joint. ELEC-2-2 Fig 11.
2 Using the correct sized splice, attach the new section of wire required or auxiliary flying lead to the existing harness and secure using the crimp tool. K Fig 11. ( T C-174) . Note that each of the splices detailed is colour-coded to make size and range C-174 C-174 9803/9880-3 Part No. Description Qty 892/00350 Butane Heater assembly 1 892/00349 Crimp tool 1 892/00351 Splice 0.5-1.5 mm (Red) 50 892/00352 Splice 1.5-2.5 mm (Blue) 50 892/00353 Splice 3.0-6.0 mm (Yellow) 50