JCB — 49.pdf (p.49)

Section C - Electrics Service Procedure Battery Battery Maintenance TC-001_4 !M WARNING To ensure that the battery provides optimum performance the following steps should be observed: Batteries give off an explosive gas. Do not smoke when handling or working on the battery. Keep the battery away from sparks and flames. 1 Make sure that the electrical connections are clean and tight. Smear petroleum jelly on connectors to prevent corrosion. Battery electrolyte contains sulphuric acid. It can burn you if it touches your skin or eyes. Wear goggles. Handle the battery carefully to prevent spillage. Keep metallic items (watches, rings, zips etc) away from the battery terminals.

Such items could short the terminals and burn you. 2 When applicable - never allow the electrolyte level to fall below the recommended level - 6 mm (1/4 in) above the plates. Use only distilled water for topping up. 3 Keep the battery at least three quarters charged, otherwise the plates may become sulphated (hardened) - this condition makes recharging the battery very difficult. Set all switches to OFF before disconnecting and connecting the battery. When disconnecting the battery, take off the earth (-) lead first. Re-charge the battery away from the machine, in a well ventilated area. Switch the charging circuit off before connecting or disconnecting the battery.

When you have installed the battery in the machine, wait five minutes before connecting it up. Extra precautions must be taken when bench charging maintenance free batteries, they are more prone to damage by overcharging than the standard type of battery: Never boost-charge a maintenance free battery. When reconnecting, fit the positive (+) lead first. Never charge a maintenance free battery at a voltage in excess of 15.8 Volts. 5-3-4-12 Never continue to charge a maintenance free battery after it begins to gas. Testing This test is to determine the electrical condition of the battery and to give an indication of the remaining useful 'life'.

Before testing ensure that the battery is at least 75% charged (SG of 1.23 to 1.25 for ambient temperature up to 27°C). Ensure that the battery is completely disconnected from the vehicle. Connect up the battery tester as follows: 1 Set the CHECK/LOAD switch 10-A to OFF. 2 Set rocker switch 10-B to the battery voltage (12V). 3 Connect the red flying lead to the battery positive (+) terminal and the black flying lead to the battery negative (-) terminal. C-171 C-171 9803/9880-3