Section E - Hydraulics Circuit Descriptions Dipper In Dipper In For schematic, K Fig 14. ( T E-43) Servo pressure from the hand controller 50 is sent to port A6 of the servo shuttle valve 46 and is distributed to: 1 Port C9 to activate the auto pressure switch 43 . 2 Port B6 to port A on the cushion valve 49 , through the valve leaving at port C (if machine is fitted with HBCV, pressure is also sent via port A1 to port P on the HBCV to allow trapped oil in the ram to exit). From port C to port Pb5 on the main control valve 14 to the dipper (1) spool, dipper (2) spool, dipper holding valve the upper pressure switch.
Flow from pump 2 enters main control valve 14 at P1 and is available at the dipper (1) spool via the left hand neutral gallery, or after passing over the straight line travel spool via the parallel working passage. At the dipper (1) spool the flow is diverted to the dipper ram 3 . Pressure is sensed at the regeneration spool RGS and moves it to the lesser restricted position. Flow from pump 1 is blocked at the dipper (2) spool and joins the flow of pump 2 before the dipper (1) spool. The pressure from both pumps is now cut off from the negative control ports Ps1 and Ps2. This reduced pressure is sensed at both pumps which now come into full flow.
Exhaust oil from the ram passes (through the HBCV if fitted) to the main control valve 14 at port A5 through the dipper hold check valve DHV (that has been released by servo pressure) to the dipper (1) spool. Exhaust oil from the dipper ram 3 can be at a "higher" pressure than the feed oil due to the effect of gravity on the dipper arm when first selected. This causes the regeneration check valve RG to open, feeding a proportion of exhaust oil into the feed side. The remaining exhaust oil returns to tank passing over the regeneration spool RGS . The regeneration spool has two restrictors, one more restricted than the other.
The restrictors cause back pressure encouraging the regeneration check valve to open. As the pressure drops the regeneration spool moves across to the less restricted position. When the feed pressure is greater than the exhaust pressure the regeneration check valve will move to the unrestricted position allowing return oil to free flow to tank. E-42 E-42 9803/9880-3