Section E - Hydraulics Remote Control Valve (Hand Control) Removal and Replacement Removal and Replacement !M WARNING 9 Lift the remote control valve clear of the arm rest. Hydraulic Pressure Hydraulic fluid at system pressure can injure you. Before connecting or removing any hydraulic hose, residual hydraulic pressure trapped in the service hose line must be vented. Make sure the hose service line has been vented before connecting or removing hoses. Make sure the engine cannot be started while the hoses are open. Note: Care should be taken when removing right arm rest, remove switches, using a thin flat bladed screw driver and disconnect electrical connections.

Replacement Replacement is the reversal of the removal sequence. INT-3-1-11_2 Note: All hydraulic adapters that are installed together with a bonded sealing washer must also have JCB Threadseal applied to the threads of the adapter. !M WARNING Fluid Under Pressure Fine jets of fluid at high pressure can penetrate the skin. Keep face and hands well clear of fluid under pressure and wear protective glasses and gloves. Hold a piece of cardboard close to suspected leaks and then inspect the cardboard for signs of fluid. If fluid penetrates your skin, get medical help immediately. INT-3-1-10_3 Removal 1 Lower dipper and place bucket on the ground 2 Turn off engine.

3 Operate both control joysticks back and forth and side to side to vent residual pressure. 4 Remove the two screws A from each side, and loosen screws B (one either side of the arm rest). Remove front panel C . 5 Disconnect electrical connection to remote control valve. 6 Disconnect all hydraulic hoses and pipes from the remote control valve and plug all orifices to prevent ingress of dirt. Label each hose before disconnecting, this will ensure correct position when refitting. 7 Remove the two screws D , two screws E and loosen the two screws F . Remove panel G . 8 Lift up gaiter H and remove the fours bolts holding the valve to the arm rest. E-103 E-103 9803/9880-3