JCB — 4.pdf (p.4)

Section E - Hydraulics Fault Finding Slew Motor Slew Motor Table 4. E-238 E-238 9803/9880-3 Symptom Cause External Inspection Countermeasure Repair Motor does not run Internal damage to the motor. Measure the oil drain volume. High possibility of damage to the sliding surfaces if the supply volume is approximately equal to the drain volume. Dismantle and inspect. K Table 5. ( T E-239). Internal damage to the motor. Open the motor inlet and outlet ports and apply 20 kgf/cm2 (284 lbf/in2) pilot pressure to the brake release port. Try to rotate the shaft with a torque of approx. 39 Nm (29 lbf ft).

High possibility of internal damage to the motor if the supply shaft does not rotate smoothly when this torque is applied. Dismantle and inspect. Renew damaged parts or renew the motor assembly. Relief valve in circuit not set correctly. Measure pressure. Reset to the prescribed setting. Excessive slip Wear or damage to the motor sliding surfaces or to the high-pressure seal. Measure the oil drain volume. Leakage is too high if the oil drain volume exceeds 5 l/min (1.1 gal/min). Dismantle and inspect. K Table 5. ( T E-239). Oil hot and excessive parts or circuit. Measure the oil temperature. Reduce the oil temperature. K Table 5. ( T E-239).

Abnormal heating Seizure of motor sliding parts or circuit. Check for any metallic matter deposited in motor drain oil or drain filter. Apply a 30 kgf/cm2 (427 lbf/in2) pilot pressure to the brake release port and try to rotate the shaft with a torque of approx.39 Nm (29 lbf ft). If metallic matter is discovered or the supply shaft does not rotate smoothly when torque is applied, there is a high possibility of internal damage to the motor. Dismantle and inspect. Repair or renew the damaged parts. Renew the motor assembly. Leakage from oil seals Damage or wear to oil seal lip. Renew the oil seals. Damage or wear of the shaft seal. Repair the problem or renew the motor assembly.

Abnormal pressure in the casing. Check the pressure in the casing and measure the drain volume. Set the pressure in the casing below 3 kg/cm2. (43 lbf/in2) Dismantle and inspect if drain volume is excessive. Renew the oil seal. Repair or renew the damaged parts. Renew the motor assembly.