JCB — 5.pdf (p.5)

Section E - Hydraulics Fault Finding Hydraulic Pump Hydraulic Pump Often the regulator and attendant valves or pump are combined which makes it very difficult to discover the reason for the trouble. Inspect the following categories which will assist in discovering the abnormal point. 2 Abnormal Vibration and Sound. Check to see if there is any abnormal vibration or sound in the pump main body. Check to see if it is like the regular frequency sound of the regulator's working or attendant valve relief working. If it is an abnormal vibration or sound, it is possible that there is damage or cavitation inside the pump. 1 Filter and Drain Oil Inspection. Inspect the filter element.

Check to see whether there is an abnormally large amount of foreign matter. There will be a small amount of metallic powder due to wear of the shoe or cylinder, but if there is a large amount of metallic powder in the filter, it may be due to trouble with the shoe. Also check the drain oil in the pump casing. 3 Measure Pressure of Each Part. When it is a control problem, do not unnecessarily open ports for inspection purposes, measure the pressure for each section and find the abnormal item. Table 6. Prime Mover Overload Table 7. When pump flow is extremely low, delivery pressures does not increase Table 8.

Abnormal Sound and Vibration E-240 E-240 9803/9880-3 Cause Treatment Note Are the revolutions - pressure higher than pre-determined values? Set to pre-determined value. Is the regulator torque setting too high? Re-inspect regulator. Refer to regulator instructions. Seizure or damage of pumps internal parts Replace damaged parts. Check the filter or drain oil for signs of abnormal wear. Wrong regulator hose connection. Correct hose lines. Cause Treatment Note Regulator breakdown Repair the regulator Refer to regulator instructions Seizure or damage of pump internal parts. Replace damaged parts. Check filter, drain oil. Pump breakdown. Replace damaged parts.

Remove pump and inspect shaft coupling. Attendant valve breakdown. Inspect attendant valve. Incorrect regulator hose connection. Correct hose lines. Cause Treatment Note Cavitation. Prevent cavitation. Check to see if hydraulic oil is white and cloudy. Boost pressure is low. Pump is broken. Air is sucked by suction pipe. Suction resistance is high. Damage of shoe caulking part. Replace piston, shoe, shoe plate. Crack in cylinder. Replace cylinder Bad installation of pump. Correct installation. Relief valve bouncing. Repair relief valve. Refer to relief valve instructions.