JCB — 55.pdf (p.55)

Section 3 - Maintenance Routine Maintenance Fuel System Bleeding the System Air in the fuel system could cause misfiring or failure to start. Air will enter the system if any part of it is disconnected or emptied. Note: Running the engine with air in the system could damage the fuel injection pump. After maintenance, remove air from the fuel system as detailed below. 1 Prepare the machine. K Prepare the Machine for Maintenance ( T 3-29) . A 2 Locate the fuel filter A , K Fig 55. ( T 3-79) . 3 Loosen the air bleeder plug B and operate the priming pump C until fuel appears at plug B . B 4 Tighten plug B and operate pump C until the fuel filter is filled with fuel.

C 5 Wait approximately one minute and loosen air bleeder plug B to bleed any air from the fuel filter. 6 Repeat the previous three steps until no air comes from the bleeder plug B . D E 7 Tighten the plug B securely and wipe off any spilt fuel. Fig 55. 8 Start the engine but do not increase engine speed. If the engine fails to start repeat procedure from step 5. 9 After engine start up, keep at idle speed for five seconds before increasing speed slowly for three minutes. 10 Use throttle dial to operate the machine at maximum speed. 11 Stop machine and check for leaks. 3-79 3-79 9803/JSM-0412