Section 3 - Maintenance Routine Maintenance Fuel System Draining the Main Filter/Sedimenter Changing the Main Filter/Sedimenter Element The fuel filter housing contains a float which moves up and down in accordance with the amount of separated water. Drain any water in the bowl as follows. 1 Prepare the machine. K Prepare the Machine for Maintenance ( T 3-29) . 1 Prepare the machine. K Prepare the Machine for Maintenance ( T 3-29) . 2 Locate the fuel filter A , K Fig 54. ( T 3-78) . 3 Loosen the air bleeder plug B and open tap C to drain fuel from the filter into a suitable container 2 Locate the fuel filter A , K Fig 55. ( T 3-79) . 4 Using filter wrench, part no.
892/01236, unscrew the filter bowl D from the filter head. 5 Remove seal and filter element E . 6 Smear the new sealing ring with fuel oil and fit with filter element into bowl D . 7 Refit bowl to filter head and tighten using filter wrench, part no. 892/01236. A 8 Wipe up any spilt fuel. 9 Bleed the fuel system. B C D E Fig 53. 3 Loosen the air bleeder plug B and open tap E to drain any water in the bowl. 4 After draining, close tap E and ensure air bleeder plug B is closed. 5 Wipe up any spilt fuel. 6 Bleed the fuel system. 3-77 3-77 9803/JSM-0412