Section B - Body and Framework Fault Finding Air Conditioning TB-010_2 Preliminary Checks Before any checks are carried out on the refrigerant circuit the following checks should be made: 1 Check the compressor drive belt is serviceable and correctly tensioned. 2 Check the condenser and engine radiator are not blocked by debris, clean with compressed air or water if necessary. 3 Check that the condenser fins are not flattened or damaged, the fins must allow air to pass freely. 4 Check the cab fresh air inlet filter for blockage. 5 Check that, with the ignition switch on (engine not running), the blower operates over whole speed range.
6 Check that, with the ignition switch on (engine not running), the blower and air conditioning switched on, the compressor clutch engages. Charge level: Note: It is not possible to check refrigerant charge level with R134a systems using the receiver drier sightglass. Any bubbles seen at the sight glass on the receiver drier may be bubbles of oil and are perfectly normal. Gas -1400g R134A +/- 10g Oil - 150g +/- 5g PAG (PolyAlkylene Gycol) oil to ISO 100 Fault finding: Important: Refer to appropriate remove and replace procedures before working on any system component B-15 B-15 9803/9880-3