Section C - Electrics Basic System Operation Pulse Width Modulation (PWM) Pulse Width Modulation (PWM) Ohms law states that, the amount of current flow in a circuit is determined by the voltage, and the resistance. A 24v circuit with a resistance of 6 ohms, would draw a current of 4 amps. This would be the case for a standard solenoid, which is either on or off. The graph A although unstable would give a current rating of three amps. To stabilize the current in the circuit, the frequency would need to be increased. If the time scale on the graph A was one second, the frequency would be 4Hz (Hertz (cycles per second)). The graph B shows the same duty cycle, but at a higher frequency of 32 Hz.
The proportional solenoids fitted to JS machines operate at a frequency of 75 Hz. Once the voltage is applied to the circuit, it is present 100% of the time. This would be known as a 100% duty cycle. Therefore the circuit will draw 4 amps constantly. C007260GB-2 Fig 15. C007270GB-2 Fig 16. A proportional solenoid requires differing amounts of current, depending on its condition. As the coil has a fixed resistance, changing the current rating can be done in either of two ways, 1 Having lots of different resistors switched in and out of the circuit at different times to change the current flowing. 2 To change the duty cycle of the solenoid.
It is easier, more economical, and more reliable to change the duty cycle of the circuit, especially using today's computer/ controller technology. The duty cycle is the amount of time a component is switched on compared to the time it is switched off. If a solenoid is on for three seconds, then off for one second, on for three, off for one etc. this would be a 75% duty cycle. C-14 C-14 9803/9880-3