OM2049 2/13 Safety - Section 20 Page 20-13 CAPACITOR DISCHARGE SYSTEM The control cabinets are equipped with two capacitor charge lights, one on the exterior of the cabinet and one in the interior. The capacitor charge lights, when off, indicate to service personnel that the drive sys- tem is safe to work on. Certain drive system failures, however, can result in a condition where one or more capacitors can remain in a charged state even though the capacitor charge lights are off.
Personal Protective Equipment (PPE) for working with 2000 VDC meter (safety shoes, high voltage gloves, and safety glasses) Multimeter for ground resistance measurement Grounding stick pair (Figure 20-5) (Komatsu Kit p/n 58B-06-00800) (HVR Advanced Power Components MAS- 000039 Ground Stick Pair or equivalent) Because a danger can still exist with the capacitor charge lights off, it is necessary to adhere to the fol- lowing instructions before touching or servicing drive system components. Only authorized service person- nel are allowed to service the drive system. Refer to the shop manual for rules when servicing the drive system.
Adhere to the proper procedures for disabling the drive system. Necessary Tools 2000 VDC meter (Figure 20-4) (Komatsu Kit p/n 58B-06-00800 (Bierer RCDC 1000 or equivalent) FIGURE 20-5. GROUNDING STICKS FIGURE 20-4. VOLT METER