Komatsu — SHORT ISOLATED CAPACITOR TERMINALS

Safety - Section 20 2/13 OM2049 Page 20-22 SHORT ISOLATED CAPACITOR TERMINALS Any capacitor that is isolated from the DC link and confirmed discharged must have its terminals electri- cally shorted together to prevent static charge build up. Use bare wire to jumper all four terminals on the capacitor. See Figure 20-13. Proceed to troubleshoot and repair the control group to restore it to original functionality. Hazardous voltages may be present in this equip- ment even if the engine and Capacitor Charge lights are off. Use measurement and protective equipment rated for 2000 VDC minimum to verify that no voltage is present before touching any terminal.

Verify functionality of the measurement equip- ment using site-approved procedures both before and after performing control group mea- surements. Failure to observe these precautions may result in death or serious personal injury. FIGURE 20-13. JUMPER ALL TERMINALS ON ISOLATED CAPACITOR