Komatsu — 10 HOUR (DAILY) INSPECTION CHECKS

OM4066 Lubrication & Service - Section 40 Page 40-1 SOUND ATTENUATION SYSTEM SERVICE INTERVALS Recommended preventive maintenance will contrib- ute to the long life and dependability of the truck and its components. The use of proper checks and adjustments at the recommended intervals is most important. The service intervals presented here are in hours of operation. However, if the truck is being operated under extreme conditions, some or all, of the inter- vals may need to be shortened and the service per- formed more frequently. 10 HOUR (DAILY) INSPECTION CHECKS EVERY 10 HOUR (DAILY) MAINTENANCE Item Task Exhaust System Inspect exhaust blankets for incorrect placement or damage.

Re-install correctly or replace blankets if any signs of damage. Inspect the exhaust for signs of significant exhaust leaks or cracks. Cracks can be welded or the part can be replaced if cracking is extensive. Retarding Grid Inspect visible air flow paths for debris or mud. Do not remove any baffles to perform inspection. Remove any debris found in the air flow paths. Screens may be removed to remove the debris. Screen mounting hardware torque is (30 ft lb). DO NOT use an impact wrench to tighten. Alternator Air Intake Silencer Inspect visible air flow paths for debris or mud. Replace silencer element if any defects are found. Do not remove any baffles or screens to perform inspection.