Komatsu — EVERY 1000 HOURS SERVICE

. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE 7. Loosen wing bolt (4) which is fixing lever (5) of priming pump (3). Move lever (5) up and down to let fuel flow out of air bleeding plug (2) until bubbles do not come out any more. 8. Tighten air bleeding plug (2) and then tighten wing bolt (4) of Tightening torque for air bleeding plug 7.8 to 9.8Nm {0.8 to 1kgm} Tightening torque for wing screw 6.9 to 12.7Nm {0.7 to 1.3kgm, 5.1 to 9.4 lbft} priming pump (3) securely to lock lever (5). If REPLACE FUEL TANK BREATHER ELEMENT WARNING 3. Install cover (3) and nut (2). 4 - 66 9.

After replacing the filter ca that there is no leakage of fuel from the filter seal surface there is any leakage of fu el, check the tightening of the fil cartridge. If there is still lea kage of fuel, follow step 1 and 2 remove the filter cartridge, then check the packing surface damage or foreign materia l. If any damage or foreign mate is found in the packing, re then repeat steps 3 - 9 to i Immediately after the engine is sto pped, its parts and oil are still very h ot, and may cause burn injury. A ccordingly, wait until they have cooled down before starting the work. 1. Remove nut (2) of breathe r assembly (1) at the top surface the fuel tank, then remove 2. Replace breather element