Komatsu — CHANGE THE HYDRAULIC OIL FILTER

MAINTENANCE CHANGE THE HYDRAULIC OIL FILTER After operating the machine, the hydraulic oil is very hot. Let the oil cool down until it is about 40° to 45 ° C (104° to 113 ° F) before changing it. The hydraulic system is pressurized. Thus, loosen the fill cap slowly to release any residual pressure inside the tank. Oils, filters, coolant, and the battery are considered special waste and must be collected and disposed of according to all antipollution regulations. The filter is on the hydraulic system drain outlet. This filter prevents metal particles from circulating through the system, which would dam- age seals and scratch highly polished chrome rods.

Using a 17 mm hexa- gon wrench, remove the screws (2). And then remove the upper platform (1) to access the hydraulic oil filter. 1. Using a 24 mm wrench, remove the filler cap (3). 2. Remove the screws (4) securing the filter cover (5). 3. Remove the cartridge (6). 3-48 WB140PS-2N WB150PS-2N