24. SERVICE PROCEDURE 1. Stop the engine and tighten up corrosion resistor valves 1 . 2. Turn radiator cap 2 slowly to remove it. 3. Prepare a container to catch the coolant, then open drain valve 3 at the radiator left lower portion to drain the coolant. 4. After draining the water, close drain valve 3 , and fill with city water. 5. When the radiator is full of water, start the engine and run it at low idling. Open drain valve 3 , run the engine at low idling, and flush water through the system for 10 minutes. When doing this, adjust the speed of filling and draining the water so that the radiator is always full.
While flushing water through the system, watch carefully that the water inlet hose does not come out of the radiator water filler. 6. After flushing, stop the engine, open drain valve 3 , then close it again after all the water has drained out. 7. After draining the water, clean with a flushing agent. For details of the cleaning method, see the instructions given with the cleaning agent. 8. After cleaning, open drain valve 3 to drain all the cooling water, then close them and fill slowly with clean water. 9.
When the water comes up to near the water filler port, open drain valve 3 , run the engine at low idling, and continue to run water through the system until clean colorless water comes out. When doing this, adjust the speed of filling and draining the water so that the radiator is always full. 10. When the water is completely clean, stop the engine, close drain valve 3 . 3-27