24. SERVICE PROCEDURE 11. Replace the corrosion resistor cartridge and open valves 1 . For details of replacement of the corrosion resistor, see "24.8 EVERY 1000 HOURS SERVICE". 12. Add cooling water until it overflows from the water filler. 13. To remove the air in the cooling water, run for 5 minutes at low idling, then for another five minutes at high idling. When doing this, leave radiator cap 2 off. 14 Drain the coolant inside sub-tank 4 , then clean the inside of the sub-tank and fill again with water to a point between the FULL and LOW lines. FULL 15. Stop the engine, wait for about 3 minutes, add cooling water up to near the radiator water filler port, then tighten the cap.
LOW AE072720 3-28