Komatsu — VALVE CALIBRATION

TESTING AND ADJUSTMENTS VALVE CALIBRATION VALVE CALIBRATION 1. HST valve calibration 1 - Loosen the nut (1), taking care not to move the adjust- ment screw (2). 2 - Adjust the working pressure of the HST valve, procee- ding as follows: To INCREASE pressure, turn the screw (2) in a CLOCKWISE direction. To REDUCE pressure, turn the screw (2) in a COUNTER-CLOCKWISE direction. # One complete turn of the screw (2) varies the pres- sure by 15.5 bar. 3 - Tighten the nut (1) and check that the working pressure remains within permissible limits. 2 1 Nut: 58.8 78.5 Nm Section A - A RKS01340 2.

AS valve calibration (only for SK815-5) Pressure adjustment at low idling A 1 - Loosen the nut (1), and adjust the working pressure of the AS valve (with the engine at low idling), proceeding as follows: To INCREASE pressure, turn the screw (2) in a CLOCKWISE direction. To REDUCE pressure, turn the screw (2) in a COUNTER-CLOCKWISE direction. # One complete turn of the screw (2) varies the pres- sure by 3.37 bar. A RKS01350 3 - Tighten the nut (1) and check that the working pressure remains within permissible limits. Nut: 34.3 58.8 Nm 1 2 Section A - A RKS01360 20-28 SK714-5 SK815-5 A A TOP VIEW RKS01330