Komatsu — TESTING THE HYDRAULIC PUMP

TESTING AND ADJUSTMENTS TESTING THE HYDRAULIC PUMP TESTING THE HYDRAULIC PUMP 1. Check the working pressure of the travel circuit HST charge valve # Test conditions: Engine: high idling Hydraulic oil temperature: 45 55 °C. Safety bar: raised 1 Do not activate the travel lever. 1 - Remove the plugs (1) and (2) and mount the two pres- sure adapters E5 . 2 - Connect two pressure gauges E1 (60 bar), start the en- gine and accelerate to high idling. TOP VIEW RKS01300 3 - Check that the pressure remains within permissible li- mits. # Use the lower of the two pressure values taken. # Normal pressure: 25 29.5 bar 2 4 - Remove the pressure adaptersand tighten the plugs(1) and (2). Plugs:

19.6 27.4 Nm BOTTOM VIEW RKS01310 2. Check the working pressure of the AS valve (Only for SK815-5) # Test conditions: Engine: high idling Hydraulic oil temperature: 45 55 °C. Safety bar: lowered Machine: raised from the ground 1 1 - Remove the plug (1) and mount a pressure adapter E5. 2 - Connect a pressure gauge E1 (60 bar) and start the en- gine at low idling (1100 rpm). L.H. SIDE VIEW RKS01320 3 - Push the travel lever full stroke for forward travel and read the pressure. # Normal value: 12.7 0.5 bar 4 - Repeat the reading with the engine at working speed (2800 30 rpm). # Normal value: 15.2 0.5 bar 5 - Remove the pressure adapter and tighten the plug (1). Plugs:

19.8 27.4 Nm 20-27 SK714-5 SK815-5