Komatsu — CONTROL VALVE

TESTING AND ADJUSTMENTS CONTROL VALVE CONTROL VALVE 1. Control of operating pressure (unloading valve) 1 - Remove the plug (1) and mount a pressure adapter. 2 - Connect a pressure gauge E3 (10 bar). E 3 3 - Start the engine and bring it up to high idling with all le- vers in neutral position. 1 4 - Check the pressure. # Normal pressure: 4.8 bar tTake care do not operate the equipment levers. The unloading valve cannot be re-adjusted. If the pressure differs from the normal value the valve must be substituted. RKSA0180 2. Control the operating pressures of the working equipment E 2 1 - Remove the plug (1) and mount a pressure adapter. 1 2 - Connect a pressure gauge E2 (400 bar or 600 bar).

3 - Start the engine and bring it up to high idling. 4 - Check the pressure for each movement with the com- mand lever at the end of its stroke and with the pressure stabilised. To check the pressure of the working equipment, push the piston to the end of its stroke. RKSA0190 Valve adjustment # The unloading valve cannot be re-adjusted, only sub- stituted. 1. Adjustment of the main relief valve If the pressures measured for the working equipment and machine travel do not fall within normal values, adjust the main relief valve (1) as follows: A A 1 - Loosen the lock nut (2) and rotate the adjusting screw (3). To INCREASE pressure, turn in a CLOCKWISE di- rection.

To DECREASE pressure, turn in a COUNTER- CLOCKWISE direction. # Each turn of the adjusting screw (3)varies the pres- sure by about 55 bar. 1 2 2 - Lock the nut (2). Nut: 69 10 Nm 3 # After adjustment, check the adjustment of the main relief valve with the same procedures as used for the measurements. Section A - A RKS01400 20-32 SK714-5 SK815-5