TESTING AND ADJUSTMENTS CONTROL AND REGULATION OF THE SERVO-CONTROL POWER SUPPLY CONTROL AND REGULATION OF THE SERVO-CONTROL POWER SUPPLY # Test conditions: Engine: at working temperature. Oil temperature: 45 55 °C. Before removing the cap to measure the pressure, re- lease the residual pressures from the circuits (See «ELIMINATION OF RESIDUAL PRESSURES OF THE CIRCUIT AND THE TANK») and put the safety device engagement levers into their locked position. After connecting the pressure gauge, pressurise the tank. For details see «PRESSURISATION OF THE TANK». 1.
Checking the pressure of the servo-controls 1 - Disconnetc the delivery pipe (1) and install a tee and a adapter; riconnect the pipe (1). E 1 2 - Connect the pressure gauge E1 (60 bar) 1 3 - Start the engine and bring it up to 2800 rpm with all leers in neutral position. 4 - Lower the safety bars and check the pressure. # Normal pressure: 25 28 bar 2. Test the pressure of the travel pilot system # Test conditions: Machine raised from the ground. RKSA0200 A2 A1 1 - Disconnect the pipe (1) of the actuator to be tested, mount a union tee and a pressure adapter, and then re- connect the pipe (1). # During travel in one direction, two actuators are never- theless activated.
Always check both pressures: B2 B1 RKS01410 20-33 SK714-5 SK815-5 Action Action involved DA1 DA2 DB1 DB2 FORWARD ❍ ❍ REVERSE ❍ ❍ RIGHT ❍ ❍ LEFT ❍ ❍