Komatsu — BLEEDING AIR FROM THE HYDRAULIC CIRCUITS

TESTING AND ADJUSTMENTS BLEEDING AIR FROM THE HYDRAULIC CIRCUITS 2. Bleeding air from the cylinders 1 - Start the engine and let it run at low idling for about 5 mi- nutes. 2 - Lower and raise the boom 4-5 times. # Lower and raise the piston of the boom up to about 100 mm of the end of its stroke. Every care must be taken to avoid pressurising the circuits. 3 - Bring the engine up to high idling and repeat the ope- rations described in point 2. Return the engine to low idling and pout the piston through its entire stroke until it reaches max. pressure in both directions. RKS01530 4 - Repeat the operation (starting from point 2) for bucket cylinder. 3.

Bleeding air from any optional equipment # This method must be used for all the optional working equipment, unless otherwise indicated. 1 - Each time an item of optional working equipment is in- stalled, operate the equipment repeatedly, with the en- gine at low idling, until all air has been completely eliminated. RKS01520 20-37 SK714-5 SK815-5