Komatsu — BLEEDING AIR FROM THE HYDRAULIC CIRCUITS

TESTING AND ADJUSTMENTS BLEEDING AIR FROM THE HYDRAULIC CIRCUITS BLEEDING AIR FROM THE HYDRAULIC CIRCUITS Sequence of operations or procedures for bleeding the air 1. Bleeding air from the pump 1 - Loosen and remove the cap (1) from the pump body (2). 2 - Pourhydraulicoilthrough the hole untilthe entirecasing is full. 2 1 3 - Replace the cap (1). # After filling the casing, start the engine and allow it to run at low idling for about 10 minutes before pro- ceding to bleed the air from the circuits.

RKSA1050 20-36 SK714-5 SK815-5 Procedures for bleeding ai 1 2 3 4 5 Bleeding air from pumps Starting engine Bleeding air from cylinders Pressurising tank Starting tasks • Substitution of hydraulic oil • Cleaning tank filter ❍ ❍ ❍ ❍ ❍ • Substitution filter ❍ ❍ ❍ ❍ • Repair - substitution pump • Removal of suction tube ❍ ❍ ❍ ❍ ❍ • Substitution - repair control valve ❍ ❍ ❍ ❍ • Repair-Substitution cylinders • Removal of cylinders tube ❍ ❍ ❍ ❍ • Repair - substitution travel motor • Removal of tubes from travel motor ❍ ❍ ❍