Komatsu — R.H. PPC VALVE (PATTERN CHANGE) (OPTIONAL)

STRUCTURE AND FUNCTION R.H. PPC VALVE (PATTERN CHANGE) (OPTIONAL) FUNCTION 1. NEUTRAL Ports P1 and P2 of the PPC valve are connected to drain chamber D through fine control hole f in spool (1). (Fig. 1) f D P T 2. During fine control (NEUTRAL fine control) When piston (4) starts to be pushed by disc (5), re- tainer (9) is pushed; spool (1) is also pushed by me- tering spring (2), and moves down. When this happens, fine control hole f is shut off from drain chamber D , and at almost the same time, it is connected to pump pressure chamber PP , so pi- lot pressure oil from the control pump passes throu- gh fine control hole f and goes to port P1 .

When the pressure at port P1 becomes higher, spo- ol(1)ispushedbackandfinecontrolhole f isshutoff from pump pressure chamber PP . At almost the same time, it is connected to drain chamber D to release the pressure at port P1 . When this happens, spool (1) moves up or down so that the force of metering spring (2) is balanced with the pressure at port P1 . The relationship in the po- sition of spool (1) and body (10) (fine control hole f is at a point midway between drain hole D and pump pressure chamber PP ) does not change even if the pressure at port P1 becomes max.

Therefore, metering spring (2) is compressed pro- portionally to the amount of movement of the control lever, so the pressure at port P1 also rises in pro- portion to the travel of the control lever. (Fig. 2) 1 P2 P1 Fig. 1 RKS00820 5 4 9 3 2 D f T P 1 PP P 2 P 1 10 Fig. 2 RKS00830 10-64 SK714-5 SK815-5