Komatsu — R.H. PPC VALVE (PATTERN CHANGE) (OPTIONAL)

STRUCTURE AND FUNCTION R.H. PPC VALVE (PATTERN CHANGE) (OPTIONAL) 3. During fine control (when the lever is returned) (fine control neutral) When disc (5) starts to be returned, spool (1) is pu- shed up by the force of centering spring (3) and the pressure at port P1 . When this happens, fine control hole f is connected to drain chamber D and the pressure oil at port P1 is released. If the pressure at port P1 drops too far, spool (1) is pushed down by metering spring (2), and fine con- trol hole f is shut off from drain chamber D .

At almost the same time, it is connected to pump pressure chamber PP , and the pump pressure is supplied until the pressure at port P1 recovers to a pressure that corresponds to the lever position. (Fig. 3). 5 4 9 3 2 D f T P f 1 P P P 2 P 1 Fig. 3 RKS00840 10-65 SK714-5 SK815-5