Komatsu — L.H. PPC VALVE (STANDARD)

STRUCTURE AND FUNCTION L.H. PPC VALVE (STANDARD) FUNCTION 1. NEUTRAL Ports P1 and P2 of the PPC valve are connected to drain chamber D through fine control hole f in spool (1). (Fig. 1) 2. During fine control (NEUTRAL fine control) When piston (4) starts to be pushed by disc (5), re- tainer (9) is pushed; spool (1) is also pushed by me- tering spring (2), and moves down. When this happens, fine control hole f is shut off from drain chamber D , and at almost the same time, it is connected to pump pressure chamber PP , so pi- lot pressure oil from the control pump passes throu- gh fine control hole f and goes from port P1 .

When the pressure at port P1 becomes higher, spo- ol(1)ispushedbackandfinecontrolhole f isshutoff from pump pressure chamber PP . At almost the same time, it is connected to drain chamber D to release the pressure at port P1 . When this happens, spool (1) moves up or down so that the force of metering spring (2) is balanced with the pressure at port P1 . The relationship in the po- sition of spool (1) and body (10) (fine control hole f is at a point midway between drain hole D and pump pressure chamber PP ) does not change even if the pressure at port P1 becomaes max.

Therefore, metering spring (2) is compressed pro- portionally to the amount of movement of the control lever, so the pressure at port P1 also rises in pro- portion to the travel of the control lever. (Fig. 2) 10-68 SK714-5 SK815-5 f P 1 P1 (P3 Fig. 1 D T P2(P4) RKS00890 ) 5 4 3 2 D f T P 1 PP 10 P1 P2 RKS00900 Fig. 2 A B Distributore A Distributore B