STRUCTURE AND FUNCTION L.H. PPC VALVE (STANDARD) 3. During fine control (when the lever is returned) (fine control neutral) When disc (5) starts to be returned, spool (1) is pu- shed up by the force of centering spring (3) and the pressure at port P1 . When this happens, fine control hole f is connected to drain chamber D and the pressure oil at port P1 is released. If the pressure at port P1 drops too far, spool (1) is pushed down by metering spring (2), and fine con- trol hole f is shut off from drain chamber D .