daewoo DE12T / P126TI — Daewoo DE12T / P126TI User Manual

(D) System Trouble shooting SYSTEM INOPERATIVE If the engine governing system does not function, the fault may be determined by per- forming the voltage tests described in Steps 1, 2, 3, and 4. (+) and (-) refer to meter polarity. Should normal values be indicated as a result of following the trouble shooting steps, the fault may be with the actuator or the wiring to the actuator See the actuator publication for testing details. - 99 - Step Terminals Normal Reading Probable Cause Of Abnorma Reading 1 F(+) & E(-) Battery supply voltage (12 or 24 VDC) 1. DC battery power not connected. Check for blown fuse 2. Low battery voltage. 3. Wiring error. 2 C & D 1.0 VAC RMS min., while cranking 1.

Gap between speed sensor and gear teeth too great. Check gap. 2. Improper or defective wiring to the speed sensor. Resistance between terminals C and D should be 30 to 1,200 ohms. 3. Defective speed sensor. 3 P(+) & G(-) 10 VDC, Internal Supply 1. Short on terminal P (This will cause a defective unit.) 2. Defective Speed Control. 4 F(+) & A(-) 1.0~ 2.0 VDC while cranking 1. SPEED adjustment set too low 2. Short/open in actuator wiring. 3. Defective speed control. 4. Defective actuator.