daewoo DE12T / P126TI — Daewoo DE12T / P126TI User Manual

UNSATISFACTORY PERFORMANCE If the governing system functions poorly, perform the following tests. - 100 - Symptom Test Probable Fault Engine over- speeds 1. Do not crank. Apply DC power to the governor system 1. Actuator goes to full fuel. Then, dis- connect speed sensor at Terminals C & D. If actuator still at full fuel speed control unit defective. If actuator at minimum fuel position - erroneous speed signal. Check speed sensor data. 2. Manually hold the engine at the desired running speed. Measure the DC voltage between Terminals A(-) & F(+) on the speed control unit. 1. If the voltage reading is 1.0 to 2.0 VDC. a) SPEED adjustment set above desired speed.

b) Defective speed control unit. 2. If the voltage reading is above 2.0 VDC, a) Actuator or linkage binding. 3. If the voltage reading is below 1.0 VDC, a) Defective speed control unit. 4. Gain set too low. Actuator does not energize fully. 1. Measure the voltage at the battery while cranking. 1. If the voltage is less than 7V for a 12V system, or14V for a 24V system, replace the battery if it is weak or undersized. 2. Momentarily connect Terminals A and F The actuator should move to the full fuel position. 1. Actuator or battery wiring in error. 2. Actuator or linkage binding. 3. Defective actuator. 4. Fuse opens. Check for short in actua- tor or actuator wiring harness.

Engine remains below desired governed speed. 1. Measure the actuator output. Terminals A & B, while running under governor control. 1. If voltage measurement is within approximately 2 volts of the battery supply voltage, then fuel control restricted from reaching full fuel posi- tion. Possibly due to interference from the mechanical governor, carburetor spring or linkage alignment. 2. Speed setting too low.