Komatsu — REPLACE PILOT FILTER ELEMENT

. MAINTENANCE MAINTENANCE PROCEDURE REPLACE PILOT FILTER ELEMENT WARNING (2). 6. Tighten bolt (2). Tightening torque: 65 to 88 Nm (6.6 to 9.0 kgm, 48 to 65 lbft) 4 - 58 3. Clea n th e filter wit h compressed air. If there is oil on t he filter, o r if the filter is extremely dirty, wash it in a neutral agen t. A fter rinsi ng it in water, dry it thorough ly befor e using it again. If the clogging of t he filter cannot be removed b y blowi ng with air or washing in water, re place the filter with a new part. 4.

After cleaning, in sert the filte r in filte r case (3) again, open the cover at the bottom left of the operator's cab by hand , return the f ilter case to its orig inal positi on, then close th e cover. When doing th is, check that the lock is applied. After the e ngi ne is stopp ed, the part s and oil are at high temperature, so th ere is danger of burns. W ait for the temperature to go dow n before s tarting th e operation. 1. Set a container u nder drain plug (1 ) to catch t 2. Loosen bolt (2), t hen remov e filter c 3. Remove element 4. Tighten drain plu Inser