DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM 7. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the signal valve. Use a multimeter to check for 12 volts between connector X022 pin 1 and chassis ground. A. If 12 volts is not present, continue with Step 8 . 8. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the signal valve. Use a multimeter to check for 12 volts between connector X008 pin 2 and chassis ground. B. If 12 volts is found, continue with Step 9 . A.
If 12 volts is present, the open circuit is in the main frame (MF) harness between connector X022 pin 1 and connector X008 pin 2 wire 1119 white. Locate the open circuit and repair. B. If 12 volts is not present, there is an open circuit in the front frame (FF) harness between connector X008 pin 2 and connector X017 pin J3-12 wire 1119 white. Locate the open and repair. 9. Visually inspect the harness and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. A. If no damage is found, erase the fault code and continue operation. 9665 1 27/05/2004 A.10.A / 8 4